After the upgrade to DP 7.01 in some environments the rarley error IPC Invalid Packet Size
has been seen while accessing a changer or tape device. The problem might be related to a slow name resolutuion on the media agent. The INET may run into a timeout before sending data to the corresponding process. In this case you may try to increase the value for the already known omnirc variable OB2INETTIMEOUT to i.e. 30. The new value OB2INETTIMEOUT=30
has to be stored into the omnirc file on the involved media agent.
This is also true for clients behind slow WAN links. Please correct the typo OB2INETTIMEOU.
Regards,
Sebastian
Hi Sebastian,
thanks for the hint.
Best regards
Daniel
I mean cases where omnicc -import_host fails for clients behind slow WAN links. 🙂
Regards,
Sebastian