With Data Protector 9.02 a restart of a backup with failed objects may fail with the error “Invalid Message Format”. The error is caused by the introduction of the “Pause / Resume” feature in DP 9.02. As a solution you can add the variable UseJCEForRestartResume=0
to the configuration file global
. As a workaround you can restart the session using command-line omnib -restart <sessionID>
. For more information see KM014002359.
Thanks for the information ; one of my clients got the problem.
Hi Daniel,
If we restart failed object, those rerun object backup version will follow the initial backup or the latest?
Example we have Full FS backup for C, D, Config few days ago. D drive backup was failed and we successfully restart it today. Could I say I can recover D drive up to today, the C & Configuration files are older version.
How about the VEAgent Backup restart failed object? Does it apply same theory?
Regards,